Research and learning

1927

Wilson: Clouds and Electric Clearing

Read electrical clearing, then solve an original matched-sample problem to distinguish a controlled intervention from an uncalibrated droplet count.

Original learning illustration: Wilson: Clouds and Electric Clearing
Charged nuclei
Target of the historical clearing intervention
70%
Fraction in the idealised original fixture

The short answer

Removing a proposed cause before observing an effect can be more informative than collecting another striking image. The inference depends on what the intervention removes and what it leaves unchanged.

Evidence and original analysis

Make the intervention assumption visible

Invented counts with unchanged uncharged nuclei.

One counted droplet per nucleus is stipulated.
Removal modelImplied charged countConsistent with total 20?
100% clearing14Yes
70% clearing20Yes, at the boundary
50% clearing28No

Chronology

A timeline of the turning points

  1. Early work reported

    Ionisation and condensation investigated.

  2. Retrospective lecture

    A selected account of the clearing control.

The physical contrast

Wilson reported that an electric field applied before expansion removed ion-produced condensation nuclei, so their cloud did not form. Uncharged nuclei could also be produced, but were not removed by the field.

The intervention tested a property of the nuclei. It was different from deciding the direction or charge of a particle from an already recorded curved track. The later chamber applications should not obscure this earlier experimental question.

Sources for this section: [1]

An invented matched comparison

Consider two perfectly matched samples. Without clearing, 20 droplets are counted; after clearing, six. Stipulate one counted droplet per nucleus, no change to uncharged nuclei and complete removal of charged nuclei. Infer the charged and uncharged counts.

Now weaken just one assumption: suppose the field removes only half the charged nuclei. Can the same counts still be explained without changing another assumption? Find the minimum removal efficiency compatible with these observations.

Sources for this section: [1]

Reference answer

Complete removal gives 14 charged and six uncharged nuclei: 70% of the initial count is charged under this model. This is a constructed count decomposition, not a calibration of Wilsonโ€™s apparatus.

Let efficiency e be the removed fraction of C charged nuclei. The observed reduction gives eC=14. Since C cannot exceed 20, e must be at least 14/20=0.7. At e=0.5, C would be 28, exceeding the original total. That version of the model is inconsistent.

Sources for this section: [1]

What the model cannot supply

The calculation is deterministic and assumes perfect matching. Real counting efficiency, droplet merging, incomplete clearing or changed condensation conditions could break its interpretation. A cloud image without these controls is not automatically a census of ions.

Sources for this section: [1]

Continue the chronology

Biography context

Explore United Kingdom through connected lives

Connected biographies

The researcher and the record

Quick answers

Common questions

Is 70% a historical experimental result?
No. It follows only from the invented counts and specified model.
Does clearing test the same question as track curvature?
No. This task changes nuclei before condensation rather than interpreting an existing track.

Primary and institutional sources

How this history was checked

Selected historical passages are distinguished from the original teaching model. Invented inputs are not reconstructed experimental data. This article was reviewed on 31 October 2026.

  1. Nobel lecture, 12 December 1927On the Cloud Method of Making Visible Ions and the Tracks of Ionizing Particles
  2. Nobel Prize Outreach / Nobel Foundation, historical recordC. T. R. Wilson: Biographical