The short answer
A storage quantity says how much data can be held. A transfer rate says how quickly data may move under specified conditions. Read both before comparing memory records.
Compare the records
Attach the claim to the right evidence
The object and scope of a record determine which comparison it supports.
| Record or model | Establishes | Does not establish |
|---|---|---|
| Device addressing | A binary capacity calculation. | A complete module specification. |
| Module ordering table | Component composition and data width. | Measured application throughput. |
| NIST prefixes | Explicit binary/decimal byte conventions. | A product’s speed or compatibility. |
| Original r×w÷8 model | An ideal interface ceiling. | Overhead, controller behaviour or real benchmarks. |
Chronology
A timeline of the turning points
Module revision
The selected SODIMM record is revision 1.21.
Device revision
The selected component record is revision 1.03.
Hold assumptions fixed
Change width or address count separately.
Read a device table and a module table separately
Samsung’s March 2014 K4B2G1646Q sheet identifies a 2 Gb DDR3 device organised as 128M × 16. Its addressing table gives eight banks, 14 row-address bits and 10 column-address bits for that organisation. The October 2013 module sheet instead lists M471B5173QH0 as 4 GB, 512M × 64, built from eight 512M × 8 components.
The records describe different products and different levels of assembly. The module’s components are 4 Gb parts; they are not the 2 Gb device in the first sheet. A useful comparison preserves that distinction instead of silently assembling a real module from mismatched examples.
Make the unit convention explicit
NIST distinguishes MiB = 2²⁰ bytes and MB = 10⁶ bytes, with eight bits per byte. For the device’s binary address space, the count is 2³ banks × 2¹⁴ rows × 2¹⁰ columns × 16 bits = 2³¹ bits. Dividing by eight gives 2²⁸ bytes, or 256 MiB.
That is an original calculation from the addressing entries. It explains the capacity convention without changing the manufacturer’s printed 2 Gb label into a decimal measurement. Use the explicit byte count when comparing records that use different prefix conventions.
Keep a pin rate attached to its bus
Both selected sheets list an 800 MHz clock alongside 1600 Mb/s per data pin. The module table’s × 64 organisation supplies a different data width from the device’s × 16. The clock is not itself the number of transferred bits per second across the whole interface.
For an ideal calculation, let r be transfers per second per data pin and w the number of simultaneously used data pins. With one bit transferred per pin each transfer, peak bytes/s = r × w ÷ 8. The model assumes all those data pins carry useful transfers continuously; refresh, commands, turnaround, controller delays and other overhead reduce usable throughput.
Exercise: separate width, depth and rate
Use a fictional interface rated at 1600 million transfers/s per data pin. Model A has 16 data pins; Model B has 64. Calculate their ideal peak byte rates. Then double the number of stored addresses in Model A while holding its width and rate fixed. Which result changes: capacity, peak bandwidth, or both?
Treat the supplied transfer rate as decimal, 1.6 × 10⁹/s, and use eight bits per byte. These are teaching models, not a compatibility claim for the historical products. No error-correction bits, multiple channels or overlapping buses are included.
Reference answer and a usable comparison checklist
Model A gives 1.6 × 10⁹ × 16 ÷ 8 = 3.2 × 10⁹ bytes/s, or 3.2 GB/s. Model B gives 12.8 GB/s. Doubling only the address count doubles capacity; it leaves the stipulated peak transfer rate unchanged. A wider interface can change the peak rate without changing the per-pin rate.
For a real comparison, first identify device versus module, then storage organisation, byte convention, rated transfer condition and active data width. Finally ask what the application can sustain. A calculated interface ceiling is neither a measured benchmark nor a guarantee of a program’s speed.
Continue the chronology
Related history guides
Does a trained response show language understanding?
Compare how another record separates its stated quantity, method and evidential limit.
Read the timeline2022 product record ·2023 bulletin · original modelWhy daily leverage and a period return differ
Compare how another record separates its stated quantity, method and evidential limit.
Read the timelineBiography context
Explore Worldwide through connected lives
Connected biographies
People connected to these records
1952—
Kwon Oh-hyun
Semiconductor engineer and former Samsung chief executiveKwon Oh-hyun moved from semiconductor research into Samsung’s memory, System LSI and device leadership, later discussing engineering careers and leadership with students.Read biographyQuick answers
Common questions
- Does doubling capacity necessarily double bandwidth?
- No. In the exercise, address depth changes while width and transfer rate stay fixed.
- Is 1600 Mb/s per pin the same as an 800 MHz clock?
- They describe different quantities. The cited DDR tables pair those ratings; the bus width is still needed for aggregate bandwidth.
Primary and institutional sources
How this history was checked
Selected historical records are linked below. Fictional exercises are labelled, and source scope is kept separate from the strength of a conclusion. This article was reviewed on 29 October 2026.