Business · Records and learning

2013–2014 records · original unit exercise

What a DRAM capacity label leaves unanswered

Compare dated Samsung device and module tables, separate bits from bytes and clock rate from transfer rate, then calculate explicit peak-bandwidth models.

Original comparison exercise separating a stated organisation, supplied rate, unit conversion and calculated result.
2 Gb
Historical × 16 device label
× 64
Selected module data organisation
3.2 / 12.8 GB/s
Original ideal models

The short answer

A storage quantity says how much data can be held. A transfer rate says how quickly data may move under specified conditions. Read both before comparing memory records.

Compare the records

Attach the claim to the right evidence

The object and scope of a record determine which comparison it supports.

Original comparison of selected records and explicitly labelled teaching models.
Record or modelEstablishesDoes not establish
Device addressingA binary capacity calculation.A complete module specification.
Module ordering tableComponent composition and data width.Measured application throughput.
NIST prefixesExplicit binary/decimal byte conventions.A product’s speed or compatibility.
Original r×w÷8 modelAn ideal interface ceiling.Overhead, controller behaviour or real benchmarks.

Chronology

A timeline of the turning points

  1. Module revision

    The selected SODIMM record is revision 1.21.

  2. Device revision

    The selected component record is revision 1.03.

  3. Hold assumptions fixed

    Change width or address count separately.

Read a device table and a module table separately

Samsung’s March 2014 K4B2G1646Q sheet identifies a 2 Gb DDR3 device organised as 128M × 16. Its addressing table gives eight banks, 14 row-address bits and 10 column-address bits for that organisation. The October 2013 module sheet instead lists M471B5173QH0 as 4 GB, 512M × 64, built from eight 512M × 8 components.

The records describe different products and different levels of assembly. The module’s components are 4 Gb parts; they are not the 2 Gb device in the first sheet. A useful comparison preserves that distinction instead of silently assembling a real module from mismatched examples.

Sources for this section: [1] · [2]

Make the unit convention explicit

NIST distinguishes MiB = 2²⁰ bytes and MB = 10⁶ bytes, with eight bits per byte. For the device’s binary address space, the count is 2³ banks × 2¹⁴ rows × 2¹⁰ columns × 16 bits = 2³¹ bits. Dividing by eight gives 2²⁸ bytes, or 256 MiB.

That is an original calculation from the addressing entries. It explains the capacity convention without changing the manufacturer’s printed 2 Gb label into a decimal measurement. Use the explicit byte count when comparing records that use different prefix conventions.

Sources for this section: [1] · [3]

Keep a pin rate attached to its bus

Both selected sheets list an 800 MHz clock alongside 1600 Mb/s per data pin. The module table’s × 64 organisation supplies a different data width from the device’s × 16. The clock is not itself the number of transferred bits per second across the whole interface.

For an ideal calculation, let r be transfers per second per data pin and w the number of simultaneously used data pins. With one bit transferred per pin each transfer, peak bytes/s = r × w ÷ 8. The model assumes all those data pins carry useful transfers continuously; refresh, commands, turnaround, controller delays and other overhead reduce usable throughput.

Sources for this section: [1] · [2]

Exercise: separate width, depth and rate

Use a fictional interface rated at 1600 million transfers/s per data pin. Model A has 16 data pins; Model B has 64. Calculate their ideal peak byte rates. Then double the number of stored addresses in Model A while holding its width and rate fixed. Which result changes: capacity, peak bandwidth, or both?

Treat the supplied transfer rate as decimal, 1.6 × 10⁹/s, and use eight bits per byte. These are teaching models, not a compatibility claim for the historical products. No error-correction bits, multiple channels or overlapping buses are included.

Sources for this section: [1] · [2] · [3]

Reference answer and a usable comparison checklist

Model A gives 1.6 × 10⁹ × 16 ÷ 8 = 3.2 × 10⁹ bytes/s, or 3.2 GB/s. Model B gives 12.8 GB/s. Doubling only the address count doubles capacity; it leaves the stipulated peak transfer rate unchanged. A wider interface can change the peak rate without changing the per-pin rate.

For a real comparison, first identify device versus module, then storage organisation, byte convention, rated transfer condition and active data width. Finally ask what the application can sustain. A calculated interface ceiling is neither a measured benchmark nor a guarantee of a program’s speed.

Sources for this section: [1] · [2] · [3]

Continue the chronology

Biography context

Explore Worldwide through connected lives

Connected biographies

People connected to these records

South KoreaBusiness

1952—

Kwon Oh-hyun

Semiconductor engineer and former Samsung chief executiveKwon Oh-hyun moved from semiconductor research into Samsung’s memory, System LSI and device leadership, later discussing engineering careers and leadership with students.Read biography

Quick answers

Common questions

Does doubling capacity necessarily double bandwidth?
No. In the exercise, address depth changes while width and transfer rate stay fixed.
Is 1600 Mb/s per pin the same as an 800 MHz clock?
They describe different quantities. The cited DDR tables pair those ratings; the bus width is still needed for aggregate bandwidth.

Primary and institutional sources

How this history was checked

Selected historical records are linked below. Fictional exercises are labelled, and source scope is kept separate from the strength of a conclusion. This article was reviewed on 29 October 2026.

  1. Samsung Electronics; manufacturer document hosted by PC ComponentsK4B2G1646Q DDR3 x16 datasheet, revision 1.03, March 2014
  2. Samsung Electronics4Gb Q-die DDR3L unbuffered SODIMM datasheet, revision 1.21, October 2013
  3. NIST Reference on Constants, Units and UncertaintyPrefixes for binary multiples